StayEco
Let room presence guide your air conditioning.
Use radar presence sensing, qualified IR control and configurable automation to reduce unnecessary AC operation while keeping normal guest control.
- 01 / Sense the spaceStayEco ControllerRadar + IREn-suite Room SensorRadar only
- 02 / Bring presence togetherPresence constellationController and associated zones
- 03 / Apply the configurationStayEco decisionMode, vacancy duration
and relevant context - 04 / Act on the ACQualified IR actionFrom the Controller to its AC
One AC. More than one place to sense presence.
A guest can leave the bedroom without leaving the space. Associated Room Sensors extend radar presence into relevant zones, so the Controller considers more than its own position before treating the space as vacant.
Still in the space.
Not yet vacant.
Presence in an associated zone keeps the vacancy path from starting.
- 01Presence in an associated zoneVacancy path held
- 02When all associated zones are clearVacancy timing can begin
- StayEco Controller
- Senses presence and controls its AC.
- Room Sensor
- Extends presence sensing, without IR control.
Normally one Controller per independently controlled AC. Add Room Sensors where the layout needs additional presence coverage.
Give absence time.
Then act.
Choose how long vacancy must continue before StayEco acts. Use schedules and priorities to select the configured mode, with up to three qualified actions at increasing points in the same vacancy episode.
- Normal
- Night
- Pet
Configure different behavior for day-to-day use, overnight periods and stays with pets. Schedules and priorities select the applicable mode.
One vacancy episode. One shared starting point.
Configurable absence: 1–1440 minutes- Shared origin
Vacancy starts
All associated zones clear
Elapsed time starts here - Action 01
First configured time
Qualified IR action
From vacancy start - Action 02
Later in the same vacancy
Second action, if configured
From vacancy start - Action 03
Further into the same vacancy
Third action, if configured
From vacancy start
Each action time is measured from vacancy start, not from the previous action.
Monitoring onlyKeep sensing without automatic vacancy actions.
Bring back the cooling StayEco changed.
When presence returns, StayEco can restore cooling it previously modified or paused. Pending vacancy actions stop, and the return path refers to cooling already managed by StayEco.
Guests keep using their normal AC remote.
- 01 / StayEco action
Cooling managed by StayEco
- 02 / During vacancy
StayEco modifies or pauses cooling during vacancy
Managed state retained - 03 / Presence returns
Managed restoration
Pending vacancy actions stop
Managed action history is not a live reading of the AC. StayEco does not observe every change made through another remote, app or panel.
The Internet can drop. Local vacancy automation can continue.
Approved commands, relevant settings and vacancy logic stay local. The Controller can use its radar and associated Room Sensor presence to continue configured vacancy automation without Internet access.
At the property
Runs locallyLocal vacancy path available
Through the connection
Needs connectivity- Remote monitoring
- Remote configuration
- New PMS and StayControl inputs
Remote access and fresh connected inputs require connectivity. The guest's normal AC remote remains available.
Discuss your setupConnect room conditions and the next arrival.
Add temperature-driven actions with StayControl or prepare cooling around an approaching arrival using supported reservation data. Ordinary StayEco vacancy automation works without either connection.
Respond to temperature context
StayControl readings can be checked against configured ranges or conditions, allowing StayEco to apply a qualified IR action.
StayControl senses. StayEco acts.- StayControl temperature
- Configured condition
- StayEco qualified IR action
Prepare for the next arrival
Supported PMS integrations can supply reservation context for configured pre-arrival cooling and other reservation-aware energy behavior.
- Reservation context
- Arrival approaching
- Configured pre-arrival behavior
- StayEco qualified IR action
Connected behavior depends on available data, configuration and qualified AC actions.
Learn the command.
Qualify the action.
Compatible with most IR-controlled air conditioners, subject to learning and qualification during setup.
Start with the indoor AC model and the remote information. Learn the relevant commands, test their effect and qualify the actions before automatic use.
Learn commands
Test on the AC
Qualified action set
Use in automation
A toggle-only power command is not a reliable automatic ON/OFF action.
Universal remotes are not supported. Compatibility depends on the model and command behavior, not the brand alone.
Discuss AC compatibilityPlace it for presence.
Position it for control.
StayEco's battery-powered devices use IR control, so normal installations with compatible IR-controlled air conditioning require no electrical work. Placement still matters for sensing, the IR path and the zones you want to include.
1Presence coverage 2Additional zone 3IR path to AC Position the Controller
Consider radar coverage and the IR path to the AC.
Cover the relevant zones
Add and associate Room Sensors where the layout needs them.
Learn, test and configure
Qualify the commands and choose the vacancy behavior for the space.
Online support and guided setup are free. On-site installation and onboarding by MasterMind are available as paid services.
Discuss installationSee the decision behind the action.
Review Controller health, last contact, configuration and automation activity. Follow the recorded decision and the IR action issued, rather than guessing why an automation step happened.
StayEco events can also start configured StayAssist communication and follow-up workflows.
Explore StayAssist- Device health
- Reported device condition
- Last contact
- Most recent Controller contact
- Configuration
- Applied automation settings
- PresenceVacancy established
- DecisionConfigured action eligible
- ActionIR action issued
- ReturnPending vacancy path cancelled
An issued IR action is not confirmation of the AC's physical state.
Own the hardware. Skip the subscription.
StayEco is a one-time hardware purchase, with no subscription or recurrent device fee. Plan the Controllers around independently controlled AC units, then add Room Sensors where the layout needs extra presence coverage.
-
StayEco Controller
Normally one per independently controlled AC
-
Room Sensors
Additional presence coverage where needed
For larger deployments, bring device quantities, volume pricing and rollout support into one proposal.
A few practical questions.
Presence, compatibility, guest control and day-to-day operation.
Discuss your setupHow does StayEco use presence from different rooms?
The StayEco Controller uses its own radar presence sensing and associated radar-only Room Sensors in relevant zones. Presence in an associated zone prevents the space from being treated as vacant. Room Sensors extend presence coverage; they do not control another AC themselves. Placement and suitable presence information matter.
Can I choose how long StayEco waits before acting?
Yes. Absence delays can be configured from 1 to 1440 minutes, with up to three staged actions. Each action time is measured from the start of the same continuous vacancy episode, not from the previous action. Pending vacancy actions stop when presence returns.
What are Normal, Night and Pet modes?
They let you configure different behavior for day-to-day use, overnight periods and stays with pets. Schedules and priorities select the applicable mode, and monitoring-only configuration is available. These are operating profiles, not guarantees of sleeping-person detection, pet identification or pet safety.
What happens when the guest returns?
Pending vacancy actions stop. StayEco can restore cooling that it previously modified or paused, based on what StayEco itself previously changed. It does not promise to restore an unseen setting chosen through another remote, app or panel.
Does StayEco work without Internet access?
Local vacancy automation can continue using stored approved commands, relevant settings, the Controller's radar and associated Room Sensor presence. Remote monitoring, remote configuration and fresh connected inputs require connectivity. The normal AC remote remains usable.
Can guests still use the remote and choose their temperature?
Yes. Guests retain normal use of the AC remote, including during an Internet outage. StayEco does not lock the remote or prevent a guest from choosing a temperature such as 18°C. Configured automation is separate from the guest's manual controls.
Does StayEco know whether the AC is actually on or off?
No. StayEco records its decisions and issued IR actions, but does not receive authoritative physical AC-state feedback or continuously observe every change through another remote, app or panel. A command issued is not confirmation that the AC received it or changed state.
Will StayEco work with my air conditioner?
Compatible with most IR-controlled air conditioners, subject to learning and qualification during setup. The indoor AC model and remote information help assess the commands available. Universal remotes are not supported, and compatibility cannot be confirmed from the brand alone. Discuss AC compatibility
Do I need StayControl to use StayEco?
No. Ordinary StayEco vacancy automation uses its own radar presence and associated Room Sensors where needed. StayControl is an optional connection that supplies temperature readings for configured temperature-driven actions. StayControl senses; StayEco applies the qualified IR action. Explore StayControl
Do I need a PMS integration?
No. Ordinary vacancy automation does not require a reservation or PMS connection. Supported PMS integrations add reservation-aware behavior, including configured pre-arrival cooling. Available data and actions depend on the provider and setup. Explore integrations
Is electrical work required?
Not for normal installations with compatible IR-controlled air conditioning. StayEco devices are battery powered and control the AC through IR. Position the Controller for presence sensing and the IR path, add Room Sensors where needed, then learn and qualify commands during setup.
How is StayEco priced?
StayEco is a one-time hardware purchase, with no subscription or recurrent device fee. The Controller and Room Sensor quantities depend on the AC units and the layout. Discuss compatibility and deployment requirements with our team, or visit pricing for the commercial model. See pricing
See how StayEco fits your properties.
Talk through your AC units, room layouts and the automation you want to configure.